Generac error code

Code 1900 — Undervoltage

The generator ran but did not produce proper voltage. Because this fault is electrical in nature, Generac's own guidance points most diagnosis to a dealer — the short list of owner checks it does publish (mostly fuel-selection checks on Guardian models) is below.

Verified against a Generac sourceALARM · Red light
What this code means
The generator is not producing proper voltage. This could result from prolonged undervoltage or sudden voltage loss.
What triggers it
Generator output voltage is not proper — prolonged undervoltage or sudden voltage loss (dedicated article Overview, which lists its codes as 1900-1906 in the Overview and 1900-1916 in the title; see series distinctions).
Which generators it applies to
  • Guardian Series 10-26 kW (2017-present) — range 1900-1906 in dealer table
  • Next Generation Series 10-28 kW — range 1900-1907 in dealer table
Causes Generac lists
  • Often linked to fuel supply/selection issues, circuitry, firmware, or voltage production
  • Fuel jet position and controller fuel-type selection not aligned with the actual fuel source can disrupt operation, affect voltage output, and trigger an undervoltage alarm (Guardian fuel-conversion steps)
Owner-level checks Generac lists
  • Clear the alarm and manually restart the unit (never start while under load)
  • Guardian only, per article: verify the correct fuel source is selected in the controller (NG or LP); verify fuel jet position is correct; if on LP, verify fuel levels are above 30%
  • Next Generation fuel conversion is done in the Field Pro app at installation (article note) — not an owner check
  • If issues persist, contact a Generac IASD — the article states the electrical nature typically requires advanced dealer diagnosis

These are only the checks Generac itself lists for owners. Anything beyond them — internal wiring, fuel-pressure testing, transfer-switch internals, or internal repair — is dealer work, and we do not publish instructions for it.

Series differences and source notes — read carefully
Title range 1900-1916 vs Overview 1900-1906 in the same Generac article; dealer table: Guardian 1900-1906, Next Generation 1900-1907. Record the range per series, not the title range.
Dealer-only territory. Do not attempt to clear this fault and repeatedly restart the unit. If it returns after one clear-and-restart, or you are unsure it is safe to run, stop and contact a licensed Generac dealer or installer (Generac calls them IASDs). If you smell gas, hear hissing, or suspect carbon monoxide, leave the area and call your gas utility or emergency services first.For this code: Circuitry / voltage-production diagnosis is dealer-level; not transcribed. Do not publish electrical repair steps.