Skip to content
StandbyWise

Tool

Generator Sizing Calculator

Work through the loads you want backed up during an outage. The wattage defaults are typical estimates — edit any of them to match the nameplate on your own appliance. The result maps your total to real Generac air-cooled size classes (10 / 14 / 18 / 22 / 24 / 26 / 28 kW) with the headroom margin stated on the results screen.

Worksheet estimate: 5,400 running watts (1,800 W per ton — a typical estimate, not a manufacturer figure; your AC's nameplate or a dealer's measurement governs).

Two AC systems? Add the second system's tonnage by increasing the wattage of any unused load row below, or have a dealer measure both — starting current for AC compressors is the single biggest factor in real-world sizing.

What do you want backed up?

Check each load and adjust the wattage if you know yours. Defaults are typical estimates for worksheet purposes only — confirm every important load against the rating on its own appliance nameplate (usually on a sticker on the back, inside the door, or on the motor). Starting (surge) watts for motors can be 2–3× the running watts shown.

  • running W
  • running W
  • running W

    Heating with gas or oil still needs electricity for the blower.

  • running W

    Typical ½ hp. Larger pumps draw much more — check the nameplate.

  • running W
  • running W
  • running W
  • running W
  • running W
  • running W
  • running W
  • running W
  • running W
  • running W
  • running W
  • running W
  • running W
  • running W

    A single EV charger can be the biggest load in the house.

  • running W

    Electric resistance heat is usually the load that pushes a home to the largest sizes — or to load management.

Your worksheet result

Backed-up loads (running watts)
4,200 W
plus 5,400 W for AC = 9,600 W total
With headroom margin applied
11,520 W
Margin used: 20% added for motor starting surges and future loads. This margin is a worksheet convention of this tool, stated here so you can see exactly how the recommendation was reached.
Suggested Generac size class
14–18 kW range
The 14 kW class is the smallest current Generac air-cooled class that covers your worksheet total with the 20% margin; the 18 kW class gives extra room for starting surges or added loads.

Size classes are propane (LP) ratings. Most Generac models are rated lower on natural gas — for example, the Guardian 22 kW model is rated 19.5 kW on natural gas (Generac spec sheet data). If you will run on natural gas, check the NG rating of the specific model against your worksheet total, or step up a class.

This is an estimate worksheet, not a sizing decision. It sums running watts with typical-estimate defaults and one stated margin. It is not a substitute for a dealer's load calculation for your home, which measures actual starting currents, accounts for load management, and sizes to code. Get that calculation before buying — an undersized generator trips offline under load, and an oversized one costs more to buy, install, and run.

StandbyWise does not publish transfer-switch wiring or gas-line sizing instructions — that work is part of a licensed installer's job on every installation.

Safety note: this worksheet is an estimate, not a substitute for a dealer's load calculation. StandbyWise does not provide instructions for gas-line work, transfer-switch wiring, or internal generator repair. See our disclaimer.